Baton

BCA1ED-B03XAI-2500X-X11

BCA1ED-B03XAI-2500X-X11

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BCA1FD-B03XAS-1500X-X32

BCA1FD-B03XAS-1500X-X32

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BCA1FD-B03XAS-2000X-X32

BCA1FD-B03XAS-2000X-X32

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BCA1FD-B03XAS-3000X-X32

BCA1FD-B03XAS-3000X-X32

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BCA1PA-B03XBS-1000X-X11

BCA1PA-B03XBS-1000X-X11

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BCAAED-B02XAS-2000X-X11

BCAAED-B02XAS-2000X-X11

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BCABED-B02XAS-2000X-X11

BCABED-B02XAS-2000X-X11

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BCC1ED-B03XBI-2000X-X12

BCC1ED-B03XBI-2000X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCC2ED-B03XBI-1250X-XXX

BCC2ED-B03XBI-1250X-XXX

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable

BCC2ED-B03XBI-2000X-X12

BCC2ED-B03XBI-2000X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCC2PA-B02XCS-0300X-X12

BCC2PA-B02XCS-0300X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCC2PA-B02XCS-2000X-X12

BCC2PA-B02XCS-2000X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCC2PA-B02XCS-2500X-X12

BCC2PA-B02XCS-2500X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCC2PA-B33XBS-0800X-X12

BCC2PA-B33XBS-0800X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCC5PA-B03XBS-0500X-X12

BCC5PA-B03XBS-0500X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCCDPA-B02XCS-3000X-X12

BCCDPA-B02XCS-3000X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCCDPA-B03XCS-1000X-X12

BCCDPA-B03XCS-1000X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BCCDPA-B03XCS-3000X-X12

BCCDPA-B03XCS-3000X-X12

  • Frame and Handle Description: Black Body, Baton Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Double Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

D-2DEMX1NAS-4000-BXX-XXXXXBAVBXZ-X

D-2DEMX1NAS-4000-BXX-XXXXXBAVBXZ-X

  • Frame: DD-Frame
  • Mounting: NOT AVAILABLE
  • Handle Type: NOT AVAILABLE
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 40A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable

D-2DEMX1NAS-8000-BXX-XXXXXBAVBXZ-X

D-2DEMX1NAS-8000-BXX-XXXXXBAVBXZ-X

  • Frame: DD-Frame
  • Mounting: NOT AVAILABLE
  • Handle Type: NOT AVAILABLE
  • Termination: Stud (M6 or 1/4-20)
  • No of Poles: 1 pole - Metric
  • Rated voltages - Main Circuit: 80Vdc
  • Time Delay : Long Time Delay 50/60Hz or DC
  • Main Circuit Current: 80A
  • Circuit Configuration: Circuit Breaker (Series Trip Current Sensing)
  • RMU - Model: Not Applicable
  • Customer Specific: Not Applicable
  • Handle Color: Black handle, White marking
  • Handle Marking: Blank no marking
  • Mounting Orientation: Vertical, Standard Mounting , Line @ Top
  • Front Plate Marking: No Marking for Pole without Handle
  • Interphase Barrier or Cover: Not Applicable
  • Approvals: No approvals; Not for Commercial Sale without Prior arrangement with Manufacturer
  • Safety marks: Not Applicable