- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
Long Code Search
Add a space to represent gaps between sections of a part number
Displaying 601 - 650 of 2247BFQ2PA-B03XCS-0500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
BFQ2PA-B33XBS-0800X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 8A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ2ZD-A07XOX-1000X-X22
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: DC
- Circuit Configuration (Internal Construction): Switch
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BFQ3PA-B03XBS-1500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 45 Deg. Bent Screw Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ3PA-B03XBS-2000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 45 Deg. Bent Screw Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ5ED-B07XBI-1500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ5MM-B07XBW-0100X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ5PA-B02XCI-1250X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ5PA-B02XCI-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ5PA-B07XBI-1200X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 12A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ5PA-B07XBI-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ5PA-B0ZXAS-3000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQAED-B02XCS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQAPA-B02XAI-1250X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQAPA-B02XAI-2000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
BFQAPA-B02XAI-2500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BFQAPA-B02XAS-2000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQBED-B02XCS-0100X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQBED-B02XCS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQBED-B03XCS-0100X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQBPA-B02XAI-2000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQBPA-B02XAI-3000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQDPA-B03XBI-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQDPA-B03XCS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Double Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFR1MM-B02XBD-0500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Clip In Mounting
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFR1PA-B1ZXAS-1600X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Clip In Mounting
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 16A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFR1PA-B1ZXBS-1600X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Clip In Mounting
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 16A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFR1PA-B1ZXCS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Clip In Mounting
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFR1PA-B1ZXCS-1600X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Clip In Mounting
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 16A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGA1ED-B02XBS-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:25A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGA1ED-B03XCS-1600X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:16A
- Relay Trip Coils:Not Applicable
BGA1FD-B03XBS-0200X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:2A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XBS-0500X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:5A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XBS-0700X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:7A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XBS-1000X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XBS-500MX-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:500mA
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XCS-0200X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:2A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XCS-0500X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:5A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XCS-0700X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:7A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XCS-1000X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1FD-B03XCS-500MX-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:500mA
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BGA1MM-B02XBD-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGA1MM-B03XCD-0100X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay (Dual Rated)
- Main Circuit Current Ratings:1A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGA1PA-B12XBS-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:5A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGA5ED-B0ZXBS-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Special (Specify)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGACED-B1ZXAS-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking:Special (Specify)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGACED-B1ZXAS-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-Pull Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking:Special (Specify)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:25A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGC1ED-B03XBI-2000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-Pull Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGC1ED-B13XOP-250MX-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-Pull Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 250mA
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BGCAFD-B02XAS-3000X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-Pull Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)