info@cbibreakers.com  🗲 600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

Long Code Search

Add a space to represent gaps between sections of a part number

Displaying 551 - 600 of 2247

BFQ1PA-B02XBI-2000X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XBS-1250X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XBS-1500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XBS-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XCI-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XCI-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XCI-2100X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 21A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XCI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XCI-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XCS-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B03XAS-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B03XBS-1600X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B07XAI-0100X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B07XCS-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B07XCS-0500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B08XCI-1250X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B08XCS-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B0ZXAI-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXAI-2000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXAS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXAS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXAS-0700X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXAS-0800X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXBS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXBS-0700X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXBS-0800X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B0ZXCS-2500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ2MM-B02XBD-0150X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 1.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XBD-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XBD-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XBD-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XBD-0700X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XBD-0750X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XBD-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2MM-B02XOP-D1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2PA-B02XAI-0300X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ2PA-B02XAI-0500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ2PA-B02XAI-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ2PA-B02XAI-1500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

BFQ2PA-B02XBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2PA-B02XBS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ2PA-B02XCS-1600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2PA-B03XAS-2000X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable

BFQ2PA-B03XBS-0400X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2PA-B03XBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2PA-B03XBS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ2PA-B03XBS-1200X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ2PA-B03XBS-1600X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ2PA-B03XCS-0400X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets