- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:20A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Long Code Search
Add a space to represent gaps between sections of a part number
Displaying 501 - 550 of 2247BFA1PA-B02XAS-2000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
BFA1PA-B02XBS-0120X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:1.2A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFA1PA-B02XBS-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFA1PA-B02XBS-3000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:30A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFA1PA-B03XAI-0900X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings:9A
- Relay Trip Coils:Not Applicable
BFA1PA-B03XCS-1500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:15A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFA1PA-B0ZXBS-1000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Special (Specify)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
BFAAPA-B02XAS-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:5A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFACED-B02XCS-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:25A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFACMM-B02XBW-1300X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (BD + Inertia Delay)
- Main Circuit Current Ratings:13A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFACMM-B03XAD-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (Dual Rated)
- Main Circuit Current Ratings:25A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFACPA-B02XAS-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:10A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFACPA-B02XAS-2000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
- Main Circuit Current Ratings:20A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFACPA-B03XBS-1600X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle:Black Body, Push-to-Reset Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:16A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFC1ED-B03XAS-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFC1ED-B03XAS-0800X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 8A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFC1MM-B03XBD-0400X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFC1MM-B0ZXBD-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFC1MM-B0ZXBD-3000X-X22
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BFC1PA-B03XBS-2000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFC1PA-B0ZXCS-0100X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Special (Specify)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFC1ZA-B02XAI-2500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BFC5ED-B02XBI-2500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFCCFD-B03XCS-1500X-X31
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFCCPA-B02XCI-2500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ1ED-B02XBS-0750X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 7.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B02XBS-1500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
BFQ1ED-B02XBS-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B02XCS-0100X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B02XCS-0250X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 2.5A
- Relay Trip Coils: Not Applicable
BFQ1ED-B02XCS-0400X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B02XCS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B02XOP-0400X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B02XOP-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B12XCS-0400X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B12XCS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-B13XBS-0050X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 0.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1ED-D02XOX-2500D0-2412
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: 24V DC
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1MM-B02XBD-0200X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1MM-B02XBD-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1PA-B02XAI-0400X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BFQ1PA-B02XAI-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1PA-B02XAI-1200X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12A
- Relay Trip Coils: Not Applicable
BFQ1PA-B02XAI-2500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BFQ1PA-B02XAS-0300X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1PA-B02XAS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1PA-B02XAS-1500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
BFQ1PA-B02XAS-1600X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 16A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BFQ1PA-B02XAS-2000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
BFQ1PA-B02XAS-3000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Push-to-Reset Handle
- Mounting: 3/8"-32 Threadneck
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark