- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Long Code Search
Add a space to represent gaps between sections of a part number
Displaying 51 - 100 of 2247BBC1ED-B03XAS-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
BBC1ED-B03XAS-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ED-B07XOP-0300X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1FD-B03XCI-0600X-X32
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 6A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: No Safety Mark
BBC1MM-B13XBD-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B01XCI-0400X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCI-0400X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B02XCI-0600X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 6A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B02XCI-0700X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCI-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B02XCI-1250X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCS-0900X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 9A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCS-1700X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 17A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XAI-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XBS-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XBS-1500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XBS-2500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XCI-1250X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B07XBI-0300X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
BBC1PA-B07XCI-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B07XCI-2000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B07XCI-2500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B08XAI-1250X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Orange (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1ZA-B01XCI-0500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
BBC1ZA-B02XAI-2500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BBC1ZA-B02XBI-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ZA-B03XAI-1000X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ZA-B03XCI-1000X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
BBC1ZA-B06XAI-1500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Yellow (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ZA-B06XCI-1500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Yellow (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
BBC1ZA-B08XAI-1250X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Orange (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2MM-B03XAD-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2MM-B03XAD-1500X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
BBC2MM-B03XBD-0500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2MM-B03XBD-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC2MM-B03XBD-1500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC2MM-B13XBD-2500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC2PA-A03XOX-2500X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Switch
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2PA-B03XBS-0300X-XXX
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
BBC2PA-B07XAS-0200X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B01XCI-0500X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-0100X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0200X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0250X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0300X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0400X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-0700X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-1000X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-1250X-X11
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-1800X-X12
Product Type: Circuit Breaker for Equipment (CBE)
Frame: B-Frame
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 18A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark