info@cbibreakers.com  🗲 600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

No of Poles

Current Rating

Voltage Rating AC

Voltage Rating DC

Frequency

Circuit Type

Mounting

Actuator Handle

Termination

Trip Characteristics

Filter by frame:

CBi Search: A-Z List

This searchable catalog shows pre-configured, popular products already in our system.

For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.

HTabGroup

A - Z (Full Detail)
Displaying 61 - 70 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

BBC1PA-B01XCI-0400X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC1PA-B02XCI-0400X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BBC1PA-B02XCI-0600X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BBC1PA-B02XCI-0700X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC1PA-B02XCI-1000X-X12

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BBC1PA-B02XCI-1250X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC1PA-B02XCS-0900X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 9A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC1PA-B02XCS-1700X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 17A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC1PA-B03XAI-1000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BBC1PA-B03XBS-1000X-X11

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Paddle Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

Pages

Accordion View
Displaying 301 - 350 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No: BDH1PA-B0LXBS-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH1PA-B0LXBS-1600X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0LXCI-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0PXAI-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0PXBI-1600X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0PXBI-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0PXBI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0PXBI-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B0YXBS-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH1PA-B0YXCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH1PA-B1KXBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH1PA-B1LXBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH1PA-B1LXBS-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-B1LXCS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH1PA-B3LXCS-0750X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH1PA-D0LXOX-1500D0-1211

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: 12V DC
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXAI-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-0450X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 4.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-0800X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-1250X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2ED-B0LXAS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXCS-0200X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXCS-0500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXCS-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXCS-1500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXCS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B0LXCS-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B1LXCS-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B3LXCS-0200X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B3LXCS-0500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B3LXCS-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B3LXCS-1500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B3LXCS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2ED-B3LXCS-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2MM-B0KXBD-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2MM-B0KXBW-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2MM-B0LXAW-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2MM-B0LXBD-2000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2MM-B1LXBD-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2MM-D0DXOP-XD024-4XX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Relay Trip Coils: 24V DC

Part No: BDH2PA-B0BXCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2PA-B0CXCI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Part No: BDH2PA-B0CXCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2PA-B0CXCS-1200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2PA-B0CXCS-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Part No: BDH2PA-B0CXOP-1500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

Pages

List View
Displaying 181 - 210 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Part No No of Poles Framesort descending View/Order Termination
BDM1PA-B0LXAS-1500X-X12 1 B-Frame Quick connect
BDM1PA-B0LXAS-0150X-X11 1 B-Frame Quick connect
BDM1PA-B0LXAS-0200X-X11 1 B-Frame Quick connect
BDM1PA-B0LXAS-0250X-X12 1 B-Frame Quick connect
BDM1PA-B0LXAS-0300X-X11 1 B-Frame Quick connect
BDM1PA-B0LXAS-0500X-X12 1 B-Frame Quick connect
BDM1PA-B0LXAS-0050X-X11 1 B-Frame Quick connect
BDM1PA-B0LXAS-0750X-X12 1 B-Frame Quick connect
BDM1PA-B0LXAS-0800X-X11 1 B-Frame Quick connect
BDM1PA-B0LXBI-1000X-XXX 1 B-Frame Quick connect
BDM1PA-B0YXBI-1000X-X12 1 B-Frame Quick connect
BDN1FD-B0LXBS-1000X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-0100X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-1500X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-2000X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-0200X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-2500X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-3000X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-0400X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-0500X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-0600X-X32 1 B-Frame Quick connect
BDN1FD-B0LXBS-0750X-X32 1 B-Frame Quick connect
BDN1MM-B0NXBD-1500X-XXX 1 B-Frame Quick connect
BDN1PA-B0KXBS-3000X-X12 1 B-Frame Quick connect
BDN1PA-B0PXCS-1000X-XXX 1 B-Frame Quick connect
BDN3PA-B0LXBS-1000X-X11 1 B-Frame Screw: bent
BDN3PA-B0LXBS-1500X-X11 1 B-Frame Screw: bent
BDN3PA-B0LXBS-1600X-X11 1 B-Frame Screw: bent
BDN3PA-B0LXBS-2000X-X11 1 B-Frame Screw: bent
BDN3PA-B0LXBS-3000X-X11 1 B-Frame Screw: bent

Pages

Keyword Search

Add a space between keywords.

Displaying 301 - 350 of 2247

BDH1PA-B0PXBI-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PA-B0PXBI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PA-B0PXBI-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PA-B0YXBS-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PA-B0YXCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PA-B1KXBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PA-B1LXBS-0600X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PA-B1LXBS-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PA-B1LXCS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PA-B3LXCS-0750X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PA-D0LXOX-1500D0-1211

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: 12V DC
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXAI-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-0200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-0450X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 4.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-0500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-0800X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-1250X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2ED-B0LXAS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXCS-0200X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXCS-0500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXCS-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXCS-1500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXCS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B0LXCS-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B1LXCS-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B3LXCS-0200X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B3LXCS-0500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B3LXCS-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B3LXCS-1500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B3LXCS-2000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2ED-B3LXCS-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2MM-B0KXBD-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2MM-B0KXBW-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BD + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2MM-B0LXAW-1000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2MM-B0LXBD-2000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2MM-B1LXBD-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2MM-D0DXOP-XD024-4XX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Relay Trip Coils: 24V DC

BDH2PA-B0BXCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Green (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2PA-B0CXCI-2500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2PA-B0CXCS-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2PA-B0CXCS-1200X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2PA-B0CXCS-1500X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2PA-B0CXOP-1500X-XXX

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

BDH2PA-B0KXCS-0700X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2PA-B0KXCS-3000X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2PA-B0LXAI-0500X-X11

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2PA-B0LXAI-0650X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 6.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2PA-B0LXAI-1000X-X12

Frame: B-Frame
  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Pages