Part No: BDG1MM-B0LXCW-2500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CD + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1MM-B0NXBD-2000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
Part No: BDG1MM-B0PXBD-0700X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B03XBS-2000X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXAS-0200X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXAS-0400X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXAS-0800X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 8A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXCS-0500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXCS-0700X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXCS-1000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0BXCS-1500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0DXCI-1000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0HXAI-2000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
Part No: BDG1PA-B0KXCS-0050X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 0.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0KXCS-0100X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0KXCS-0200X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0KXCS-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0KXCS-0500X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0KXCS-0750X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 7.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0KXCS-1200X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 12A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0LXBS-0010X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 0.1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0LXBS-0100X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0LXBS-0500X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0LXBS-500MX-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 500mA
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG1PA-B0LXCI-2500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1PA-B0TXBS-3000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG1XX-X0XXXX-XXXXX-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Not Applicable
- Frequency: Not Applicable
- Circuit Configuration (Internal Construction): Not Applicable
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Not Applicable
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Not Applicable
- Main Circuit Current Ratings: No Rating
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
Part No: BDG2MM-B0KXBD-0500X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
Part No: BDG2MM-B0KXBD-2000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG2PA-B03XBS-2000X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
Part No: BDG2PA-B0DXAS-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0DXBS-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0DXBS-1000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
Part No: BDG2PA-B0DXBS-2500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG2PA-B0HXCI-0250X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2.5A
- Relay Trip Coils: Not Applicable
Part No: BDG2PA-B0KXBI-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0KXBI-0500X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0KXBI-0700X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0KXBI-0800X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 8A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0KXBS-0500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG2PA-B0LXAS-500MX-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 500mA
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0LXBI-2000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2PA-B0LXOP-1500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BDG2PA-B0YXAI-0200X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
Part No: BDG2PA-B0YXBI-0200X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
Part No: BDG2PA-B0YXBS-2000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BDG2ZD-A1YXOX-1000X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: DC
- Circuit Configuration (Internal Construction): Switch
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
Part No: BDG3MM-B0NXAW-1000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit with 45 Deg. Bent Screw Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
Part No: BDG4MM-B0NXAW-0300X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit WITH 45 Deg. Bent Screw Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
Part No: BDG5MM-B0KXBD-0100X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Pages
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Pages
Add a space between keywords.
Displaying 151 - 200 of 2247BDG1PA-B0BXAS-0400X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0BXAS-0800X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 8A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0BXCS-0500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0BXCS-0700X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0BXCS-1000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0BXCS-1500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0DXCI-1000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0HXAI-2000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
BDG1PA-B0KXCS-0050X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 0.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0KXCS-0100X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0KXCS-0200X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0KXCS-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0KXCS-0500X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0KXCS-0750X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 7.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0KXCS-1200X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 12A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0LXBS-0010X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 0.1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0LXBS-0100X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0LXBS-0500X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0LXBS-500MX-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 500mA
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG1PA-B0LXCI-2500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1PA-B0TXBS-3000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 30A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG1XX-X0XXXX-XXXXX-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Not Applicable
- Frequency: Not Applicable
- Circuit Configuration (Internal Construction): Not Applicable
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Not Applicable
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Not Applicable
- Main Circuit Current Ratings: No Rating
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BDG2MM-B0KXBD-0500X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
BDG2MM-B0KXBD-2000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG2PA-B03XBS-2000X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BDG2PA-B0DXAS-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0DXBS-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0DXBS-1000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
BDG2PA-B0DXBS-2500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG2PA-B0HXCI-0250X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I - O)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2.5A
- Relay Trip Coils: Not Applicable
BDG2PA-B0KXBI-0300X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0KXBI-0500X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0KXBI-0700X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0KXBI-0800X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 8A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0KXBS-0500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG2PA-B0LXAS-500MX-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 500mA
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0LXBI-2000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2PA-B0LXOP-1500X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG2PA-B0YXAI-0200X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BDG2PA-B0YXBI-0200X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BDG2PA-B0YXBS-2000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDG2ZD-A1YXOX-1000X-X22
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: DC
- Circuit Configuration (Internal Construction): Switch
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Red (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: No approvals required, refer to ticksheet
- Safety Marks: No Safety Mark
BDG3MM-B0NXAW-1000X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit with 45 Deg. Bent Screw Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
BDG4MM-B0NXAW-0300X-XXX
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit WITH 45 Deg. Bent Screw Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (On - Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AD + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
BDG5MM-B0KXBD-0100X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDG6MM-B0KXAD-1000X-X12
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Double Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (I/0 & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BDGCED-B0LXBS-1000X-X11
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDGCFD-B0LXBS-0500X-X31
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDGCFD-B0LXBS-1000X-X31
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BDGCFD-B0LXBS-1500X-X31
- Frame and Handle Description: Black Body, Rocker Handle
- Mounting: Snap-in Vertical Mounting (Without Rocker Guard)
- No of Poles and Termination: Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (I/O & On/Off)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)