This searchable catalog shows pre-configured, popular products already in our system.
For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.
HTabGroup
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Part No: BBA1PA-B02XCS-2500X-X11
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
- Main Circuit Current Ratings:25A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBA2MM-B02XBD-2000X-XXX
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit:65V DC / 240V AC MKII
- Frequency:AC / DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:White (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings:20A
- Relay Trip Coils:Not Applicable
Part No: BBAAPA-B01XCI-130MX-X12
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Green (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings:130mA
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBAAPA-B04XCI-450MX-X12
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit with 90 Deg. Bent Terminal
- Rated Voltage - Main Circuit:240V (1kA) MKII
- Frequency:AC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Blue (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings:450mA
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBACFD-B03XBS-3000X-X31
- Frame and Handle:Black Body, Paddle Handle
- Mounting:Centre Lock (Thread Neck) Metric (M12)
- No of Poles and Termination:Single Pole Unit, Screw Terminal
- Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
- Frequency:DC
- Circuit Configuration (Internal Construction):Series Trip Current Sensing
- Auxiliary Switch(es):No Auxiliary Switch
- Handle, Indicator Color & Marking:Black (No Marking)
- Voltages for Illuminated Rocker Units:Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
- Main Circuit Current Ratings:30A
- Relay Trip Coils:Not Applicable
- Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1ED-B03XAS-1000X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1ED-B03XAS-1500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1ED-B07XOP-0300X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1FD-B03XCI-0600X-X32
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 6A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1MM-B13XBD-1500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1PA-B01XCI-0400X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B02XCI-0400X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1PA-B02XCI-0600X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 6A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1PA-B02XCI-0700X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B02XCI-1000X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1PA-B02XCI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B02XCS-0900X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 9A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B02XCS-1700X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 17A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B03XAI-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B03XBS-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B03XBS-1500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B03XBS-2500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B03XCI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B07XBI-0300X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
Part No: BBC1PA-B07XCI-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B07XCI-2000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B07XCI-2500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1PA-B08XAI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Orange (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC1ZA-B01XCI-0500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
Part No: BBC1ZA-B02XAI-2500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
Part No: BBC1ZA-B02XBI-2500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1ZA-B03XAI-1000X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1ZA-B03XCI-1000X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
Part No: BBC1ZA-B06XAI-1500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Yellow (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC1ZA-B06XCI-1500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Yellow (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
Part No: BBC1ZA-B08XAI-1250X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Orange (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC2MM-B03XAD-0500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC2MM-B03XAD-1500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
Part No: BBC2MM-B03XBD-0500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC2MM-B03XBD-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC2MM-B03XBD-1500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC2MM-B13XBD-2500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC2PA-A03XOX-2500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Switch
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC2PA-B03XBS-0300X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
Part No: BBC2PA-B07XAS-0200X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC5PA-B01XCI-0500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Part No: BBC5PA-B02XCI-0100X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC5PA-B02XCI-0200X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC5PA-B02XCI-0250X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Part No: BBC5PA-B02XCI-0300X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
Pages
If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.
Pages
Add a space between keywords.
Displaying 51 - 100 of 2247BBC1ED-B03XAS-1000X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ED-B03XAS-1500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ED-B07XOP-0300X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1FD-B03XCI-0600X-X32
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
- Frequency: DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 6A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
- Safety Marks: No Safety Mark
BBC1MM-B13XBD-1500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B01XCI-0400X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCI-0400X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B02XCI-0600X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 6A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B02XCI-0700X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCI-1000X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1PA-B02XCI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCS-0900X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 9A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B02XCS-1700X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
- Main Circuit Current Ratings: 17A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XAI-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XBS-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XBS-1500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XBS-2500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B03XCI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B07XBI-0300X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
BBC1PA-B07XCI-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B07XCI-2000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 20A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B07XCI-2500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1PA-B08XAI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Orange (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC1ZA-B01XCI-0500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
BBC1ZA-B02XAI-2500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
BBC1ZA-B02XBI-2500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ZA-B03XAI-1000X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ZA-B03XCI-1000X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
BBC1ZA-B06XAI-1500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Yellow (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC1ZA-B06XCI-1500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Yellow (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
BBC1ZA-B08XAI-1250X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: Special (Specify)
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Orange (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2MM-B03XAD-0500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2MM-B03XAD-1500X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
BBC2MM-B03XBD-0500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2MM-B03XBD-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC2MM-B03XBD-1500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 15A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC2MM-B13XBD-2500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
- Frequency: AC / DC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC2PA-A03XOX-2500X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Switch
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
- Main Circuit Current Ratings: 25A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC2PA-B03XBS-0300X-XXX
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Black (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
BBC2PA-B07XAS-0200X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Double Pole Unit, Quick Connect
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Red (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B01XCI-0500X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: Green (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-0100X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 1A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0200X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0250X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 2.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0300X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 3A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark
BBC5PA-B02XCI-0400X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 4A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-0700X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 7A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-1000X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 10A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-1250X-X11
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 12.5A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
BBC5PA-B02XCI-1800X-X12
- Frame and Handle Description: Black Body, Paddle Handle
- Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
- No of Poles and Termination: Single Pole Unit, Clamp Terminal
- Rated Voltage - Main Circuit: 240V (1kA) MKII
- Frequency: AC
- Circuit Configuration (Internal Construction): Series Trip Current Sensing
- Auxiliary Switch(es): No Auxiliary Switch
- Handle, Indicator Color & Marking: White (No Marking)
- Voltages for Illuminated Rocker Units: Not Applicable
- Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
- Main Circuit Current Ratings: 18A
- Relay Trip Coils: Not Applicable
- Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
- Safety Marks: No Safety Mark