info@cbibreakers.com  🗲 600 Eagleview Blvd, Exton, PA 19341  🗲  +1 610 524 9949

No of Poles

Current Rating

Voltage Rating AC

Voltage Rating DC

Frequency

Circuit Type

Mounting

Actuator Handle

Termination

Trip Characteristics

Filter by frame:

CBi Search: A-Z List

This searchable catalog shows pre-configured, popular products already in our system.

For custom configurations, please contact us. We recommend that you identify products closest to your requirements, and then order a sample noting your custom configuration. Our representative will contact you.

HTabGroup

A - Z (Full Detail)
Displaying 681 - 690 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

BGQ2ED-B03XCS-1250X-X11

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
6 - 15 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Fast
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BGQ2MM-B0ZXAD-1000X-X12

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
6 - 15 A
Frequency: 
AC / DC
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BGQ2PA-B02XAI-1000X-X11

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BGQ2PA-B02XBS-0500X-X11

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BGQ2PA-B02XBS-2000X-X12

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BGQ2PA-B03XAI-0300X-X11

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
0.1 - 5 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BGQ2PA-B0ZXBS-1000X-X12

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Special (Specify)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BGQ2PA-B12XAS-2000X-X11

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
16 - 30 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Slow
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

BGQ2PA-B33XBS-0800X-X12

Vertical Tabs

Detail
No of Poles: 
2
Current Rating: 
6 - 15 A
Frequency: 
AC only
Voltage Rating AC: 
240V AC
Mounting: 
Panel mount: Imperial
Termination: 
Quick connect
Trip Characteristics
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark
Order Sample

BGQ3FD-B02XBS-0500X-X31

Vertical Tabs

Detail
No of Poles: 
1
Current Rating: 
0.1 - 5 A
Frequency: 
DC only
Voltage Rating DC: 
61 - 80V DC
Mounting: 
Panel mount: Imperial
Termination: 
Screw: bent
Trip Characteristics
Circuit Type: 
Series trip
Trip Characteristics: 
Medium
Downloads
Frame: 
Actuator Handle: 
Description
  • Frame and Handle Description: Black Body, Push-Pull Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit with 45 Deg. Bent Screw Terminal
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)
Order Sample

Pages

Accordion View
List View
Displaying 2041 - 2070 of 2252

If no results are displayed, please adjust your choices on the left. The first selections might be slow, as there are thousands of records to load! As you select, each remaining search parameter will recalculate.

Pages

Keyword Search