The B Series is a very compact yet robust circuit breaker for applications with space constraints. It offers a wide range of handles, and is used in applications like telecoms, lighting, railways signalling and solar power. It is available in single and double pole configurations for both AC and DC applications. There is a choice for time delay characteristics and auxiliary switch options.

Options

  • Single or double pole
  • AC, DC or dual frequency
  • Relay or Series Trip with a range of delays, with or without auxiliary switch
  • 0.1 to 30A current
  • 240V AC and up to 125V DC
  • Available in Metric or Imperial panel mounts, or Snap-in Mounts
  • Screw, Clamp or Quick Connect terminations
  • CBE Catalog Search

BDH1PAB0JXBS1600X12

BDH1PAB0JXBS1600X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0JXBS2000X11

BDH1PAB0JXBS2000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0JXBS3000X12

BDH1PAB0JXBS3000X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Orange (I - O)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0KXAI1500X12

BDH1PAB0KXAI1500X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0KXAI2000X11

BDH1PAB0KXAI2000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0KXBS1500X11

BDH1PAB0KXBS1500X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0KXBS2000X11

BDH1PAB0KXBS2000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0KXBS2500X11

BDH1PAB0KXBS2500X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0KXCS700X11

BDH1PAB0KXCS700X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 7A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0KXCS800X11

BDH1PAB0KXCS800X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0LXAS1000X12

BDH1PAB0LXAS1000X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0LXAS3000X11

BDH1PAB0LXAS3000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0LXBS1000X11

BDH1PAB0LXBS1000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0LXBS1500X12

BDH1PAB0LXBS1500X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0LXBS1600X11

BDH1PAB0LXBS1600X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0LXBS500X12

BDH1PAB0LXBS500X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0LXBS600X11

BDH1PAB0LXBS600X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0LXCI3000X11

BDH1PAB0LXCI3000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0PXAI3000X11

BDH1PAB0PXAI3000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0PXBI1600X11

BDH1PAB0PXBI1600X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0PXBI2000X11

BDH1PAB0PXBI2000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0PXBI2500X11

BDH1PAB0PXBI2500X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0PXBI3000X11

BDH1PAB0PXBI3000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (On - Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB0YXBS200X12

BDH1PAB0YXBS200X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB0YXCS1000X12

BDH1PAB0YXCS1000X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Red (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB1KXBS600X12

BDH1PAB1KXBS600X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (I/0 & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB1LXBS3000X11

BDH1PAB1LXBS3000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAB1LXBS600X12

BDH1PAB1LXBS600X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 6A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB1LXCS500X12

BDH1PAB1LXCS500X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH1PAB3LXCS750X11

BDH1PAB3LXCS750X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (0.1A -125V AC 0.1A -30V DC)
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH1PAD0LXOX1500D01211

BDH1PAD0LXOX1500D01211

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: 12V DC
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2EDB0LXAI1000X12

BDH2EDB0LXAI1000X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS1000X12

BDH2EDB0LXAS1000X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS1250X12

BDH2EDB0LXAS1250X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS1500X12

BDH2EDB0LXAS1500X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS2000X11

BDH2EDB0LXAS2000X11

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BDH2EDB0LXAS200X12

BDH2EDB0LXAS200X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS450X12

BDH2EDB0LXAS450X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 4.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS500X12

BDH2EDB0LXAS500X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BDH2EDB0LXAS800X12

BDH2EDB0LXAS800X12

  • Frame and Handle Description: Black Body, Rocker Handle
  • Mounting: Snap-in Vertical Mounting (With Rocker Guard)
  • No of Poles and Termination: Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (I/O & On/Off)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 8A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.