B-Frame

B-Frame

The B Series is a very compact yet robust circuit breaker for applications with space constraints. It offers a wide range of handles, and is used in applications like telecoms, lighting, railways signalling and solar power. It is available in single and double pole configurations for both AC and DC applications. There is a choice for time delay characteristics and auxiliary switch options.

Options

  • Single or double pole
  • AC, DC or dual frequency
  • Relay or Series Trip with a range of delays, with or without auxiliary switch
  • 0.1 to 30A current
  • 240V AC and up to 125V DC
  • Available in Metric or Imperial panel mounts, or Snap-in Mounts
  • Screw, Clamp or Quick Connect terminations
  • CBE Catalog Search

BZA1FD-B03XBS-0200X-X31

BZA1FD-B03XBS-0200X-X31

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:2A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BZA1FD-B03XBS-1000X-X31

BZA1FD-B03XBS-1000X-X31

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Medium Time Delay
  • Main Circuit Current Ratings:10A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BZA1FD-B0ZXCS-0400X-X32

BZA1FD-B0ZXCS-0400X-X32

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Special (Specify)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:4A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BZA1FD-B0ZXCS-1200X-X32

BZA1FD-B0ZXCS-1200X-X32

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Special (Specify)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:12A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BZA1FD-B0ZXCS-2000X-X32

BZA1FD-B0ZXCS-2000X-X32

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:80V Polarity Sensitive (0.6kA) MKI
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Special (Specify)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:20A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: No Safety Mark

BZA2ED-B03XCS-3000X-X12

BZA2ED-B03XCS-3000X-X12

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:65V DC (0.5kA) MKII
  • Frequency:DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:30A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZA2PA-B03XAS-1600X-X12

BZA2PA-B03XAS-1600X-X12

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:16A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZA2PA-B03XAS-2000X-X12

BZA2PA-B03XAS-2000X-X12

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:20A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZA2PA-B03XAS-2500X-X12

BZA2PA-B03XAS-2500X-X12

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Double Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay
  • Main Circuit Current Ratings:25A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZABPA-B03XCS-1000X-X12

BZABPA-B03XCS-1000X-X12

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Double Pole Unit with 90 Deg. Bent Terminal
  • Rated Voltage - Main Circuit:240V (1kA) MKII
  • Frequency:AC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Short Time Delay
  • Main Circuit Current Ratings:10A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZADMM-B03XAD-2500X-X12

BZADMM-B03XAD-2500X-X12

  • Frame and Handle:Black Body. Cut off Handle
  • Mounting:Centre Lock (Thread Neck) Metric (M12)
  • No of Poles and Termination:Double Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit:65V DC / 240V AC MKII
  • Frequency:AC / DC
  • Circuit Configuration (Internal Construction):Series Trip Current Sensing
  • Auxiliary Switch(es):No Auxiliary Switch
  • Handle, Indicator Color & Marking:Black (No Marking)
  • Voltages for Illuminated Rocker Units:Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS):Long Time Delay (Dual Rated)
  • Main Circuit Current Ratings:25A
  • Relay Trip Coils:Not Applicable
  • Approvals/Marks:UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZC1ED-B03XBI-2000X-X12

BZC1ED-B03XBI-2000X-X12

  • Frame and Handle Description: Black Body. Cut off Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BZC1PA-B03XBS-1500X-X22

BZC1PA-B03XBS-1500X-X22

  • Frame and Handle Description: Black Body. Cut off Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: No approvals required, refer to ticksheet
  • Safety Marks: No Safety Mark

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.