BFC5ED-B02XBI-2500X-X11

BFC5ED-B02XBI-2500X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Clamp Terminal
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFCCFD-B03XCS-1500X-X31

BFCCFD-B03XCS-1500X-X31

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 80V Polarity Sensitive (0.6kA) MKI
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL 489A, UL508, IEC60934,VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFCCPA-B02XCI-2500X-X11

BFCCPA-B02XCI-2500X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: Centre Lock (Thread Neck) Imperial (1/2" - 32)
  • No of Poles and Termination: Single Pole Unit, Screw Terminal
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1ED-B02XBS-0750X-X12

BFQ1ED-B02XBS-0750X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 7.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XBS-1500X-XXX

BFQ1ED-B02XBS-1500X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

BFQ1ED-B02XBS-2500X-X12

BFQ1ED-B02XBS-2500X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XCS-0100X-X12

BFQ1ED-B02XCS-0100X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 1A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XCS-0250X-XXX

BFQ1ED-B02XCS-0250X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 2.5A
  • Relay Trip Coils: Not Applicable

BFQ1ED-B02XCS-0400X-X12

BFQ1ED-B02XCS-0400X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XCS-1000X-X12

BFQ1ED-B02XCS-1000X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XOP-0400X-X12

BFQ1ED-B02XOP-0400X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B02XOP-0500X-X12

BFQ1ED-B02XOP-0500X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Instantaneous
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B12XCS-0400X-X12

BFQ1ED-B12XCS-0400X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B12XCS-1000X-X12

BFQ1ED-B12XCS-1000X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-B13XBS-0050X-X12

BFQ1ED-B13XBS-0050X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): 1 x Change-Over (3A -125V AC 3A -24V DC)
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 0.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1ED-D02XOX-2500D0-2412

BFQ1ED-D02XOX-2500D0-2412

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC (0.5kA) MKII
  • Frequency: DC
  • Circuit Configuration (Internal Construction): Relay Trip (Voltage Sensing)
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Switch
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: 24V DC
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1MM-B02XBD-0200X-X12

BFQ1MM-B02XBD-0200X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 2A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1MM-B02XBD-0500X-X12

BFQ1MM-B02XBD-0500X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 65V DC / 240V AC MKII
  • Frequency: AC / DC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (Dual Rated)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAI-0400X-X11

BFQ1PA-B02XAI-0400X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XAI-1000X-X12

BFQ1PA-B02XAI-1000X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAI-1200X-XXX

BFQ1PA-B02XAI-1200X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 12A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAI-2500X-XXX

BFQ1PA-B02XAI-2500X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay (AS + Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAS-0300X-X12

BFQ1PA-B02XAS-0300X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 3A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAS-1000X-X12

BFQ1PA-B02XAS-1000X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 10A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAS-1500X-XXX

BFQ1PA-B02XAS-1500X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAS-1600X-X12

BFQ1PA-B02XAS-1600X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XAS-2000X-XXX

BFQ1PA-B02XAS-2000X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XAS-3000X-X12

BFQ1PA-B02XAS-3000X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XBI-2000X-XXX

BFQ1PA-B02XBI-2000X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay (BS + Inertia Delay)
  • Main Circuit Current Ratings: 20A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XBS-1250X-X12

BFQ1PA-B02XBS-1250X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 12.5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XBS-1500X-X11

BFQ1PA-B02XBS-1500X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XBS-1500X-X12

BFQ1PA-B02XBS-1500X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 15A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XCI-0400X-X12

BFQ1PA-B02XCI-0400X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 4A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XCI-0500X-X12

BFQ1PA-B02XCI-0500X-X12

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 5A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: No Safety Mark

BFQ1PA-B02XCI-2100X-X11

BFQ1PA-B02XCI-2100X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 21A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XCI-2500X-X11

BFQ1PA-B02XCI-2500X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B02XCI-2500X-XXX

BFQ1PA-B02XCI-2500X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay (CS +Inertia Delay)
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B02XCS-2500X-XXX

BFQ1PA-B02XCS-2500X-XXX

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: White (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Short Time Delay
  • Main Circuit Current Ratings: 25A
  • Relay Trip Coils: Not Applicable

BFQ1PA-B03XAS-3000X-X11

BFQ1PA-B03XAS-3000X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Long Time Delay
  • Main Circuit Current Ratings: 30A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

BFQ1PA-B03XBS-1600X-X11

BFQ1PA-B03XBS-1600X-X11

  • Frame and Handle Description: Black Body, Push-to-Reset Handle
  • Mounting: 3/8"-32 Threadneck
  • No of Poles and Termination: Single Pole Unit, Quick Connect
  • Rated Voltage - Main Circuit: 240V (1kA) MKII
  • Frequency: AC
  • Circuit Configuration (Internal Construction): Series Trip Current Sensing
  • Auxiliary Switch(es): No Auxiliary Switch
  • Handle, Indicator Color & Marking: Black (No Marking)
  • Voltages for Illuminated Rocker Units: Not Applicable
  • Time Delay Characteristics (Pulse Tolerance @ 10mS): Medium Time Delay
  • Main Circuit Current Ratings: 16A
  • Relay Trip Coils: Not Applicable
  • Approvals/Marks: UL1077, UL1500, IEC60934, VDE & CE
  • Safety Marks: CCC / CRCC (refer to tick sheet for CRCC requirement)

Pages

Looking for a distributor?

Visit our map-based Distributor search to find your closest supplier. Our carefully-selected distributors help you find the right circuit breaker for your needs

Find a distributor

 

Bulk & Custom Products

Are you an equipment manufacturer in telecoms or construction? If you are looking for custom configurations or bulk purchases, please contact our sales team.

Contact us

Protect your assets

Superior circuit breakers for equipment.